Atomic Force Microscope

…in late 1990-ies. Despite seemingly old, it is still competitive with the brand-new AFMs in terms of high-resolution topography determination. It is capable of both contact and tapping modes, allowing…

Sample holders

…OMNY pin sample holders for the NanoMAX Imaging Station. Left: sample pins compatible usable at the NanoMAX imaging station. Sample preparation and mounting is essential for a successful beamtime. Discuss…

Access modes

…of fast access proposals can be found here. Proprietary access chevron_right The complete beamline setup is available for Proprietary users, please contact the MAX IV Industrial Relations Office for further…

Technical Notes

R3 beam dynamics High-Chromaticity_Optics_for_the_MAX_IV_3_GeV_Storage_Ring.pdf Internal_Note_20090902_Updated_Lattice_120614.pdf Internal_Note_20100318_Updated_Lattice_120614.pdf Internal_Note_20100512_Pulsed_Magnet_Injection_120612.pdf Internal_Note_20101101_Updated_Lattice_120614.pdf Internal_Note_20101203_Magnet_Synchronization_120612.pdf Internal_Note_20110117_Updated_Lattice_120612.pdf Internal_Note_20111124_Updated_Lattice_120611.pdf Internal_Note_20121107_Updated_Lattice_140129.pdf Internal_Note_20130724_OCO_Modeling_141009.pdf Internal_Note_20150129_MIK_Analysis_150130.pdf Internal_Note_20150930_MW_Threshold.pdf insertion devices Internal_Note_20090922_Insertion_Devices_for_the_MAX_IV_3_GeV_Storage_Ring.pdf Internal_Note_20100215_Insertion_Devices_for_the_MAX_IV_3_GeV_Ring.pdf Internal_Note_20101209_Elliptically_Polarising_Undulators_with_11_mm_Magnetic_Gap_at_the_MAX_IV_3_GeV_Ring.pdf Internal_Note_20111110_Comparison_Brilliance_MAX_IV_NSLS-II.pdf Internal_Note_20111220_Elliptically_polarizing_undulators_for_the_Arpes_beamline_at_the_Solaris_Light_Source.pdf RF cavities Internal_Note_20240410 Harmonic Cavity Parameters for Flat…

Staff

The Design Office team consists of the following people Design Office Common contact Office location: D110053 E-mail: mechanical@maxiv.lu.se Joaquin Gonzalez E-mail: joaquin.gonzalez@maxiv.lu.se Phone: +46462226511 Linus Roslund Mechanical designer Office location:…

High-Temperature Cell

…of inlet and outlet gas composition Analyser apertures 0.3 mm Gas dosing (available 2018-I) up to 8 individual gases (by user request) and their mixture. Fully automatic gas dosing system…

A record year for research at MAX IV

…Li-ion batteries Read all the Highlights in the MAX IV Annual Report 2023. 2023 in numbers: Insights from the MAX IV Annual Report +51% publications compared to 2022.  +31% unique…

Experimental station

Once completed, the DanMAX experiment station will host two instruments for powder diffraction and one for full-field imaging and tomography. Currently, we have the first of the powder diffraction instruments,…

Microscope

…of this image. Right panel: height profile along the indicated line. Comparison between STM and ncAFM imaging/resolution Sample: SiC(0001), STM: Vbias = +1.25 V, It = 230 pA AFM: Vbias…